Article:
Reliability and Validity of the Modified Mini Cog: A Measure for Screening Cognitive Functions in Literates and Non-literates

creativeworkseries.issn1999-6217
dc.contributor.authorAdhikari, Shambhu Prasad
dc.contributor.authorMahat, Reetu
dc.contributor.authorBajagain, Sapana
dc.contributor.authorShrestha, Nistha
dc.contributor.authorDonkelaar, Paul van
dc.date.accessioned2026-09-10T09:39:45Z
dc.date.available2026-09-10T09:39:45Z
dc.date.issued2025
dc.descriptionShambhu Prasad Adhikari School of Health and Exercise Sciences, University of British Columbia, Kelowna, BC, Canada. Reetu Mahat Department of Physiotherapy, Manmohan Memorial Institute of Health Sciences, Kathmandu, Nepal. Sapana Bajagain Banepa Health Care, Banepa, Kavre, Nepal. Nistha Shrestha Epidemiology and Disease Control Division, Department of Health Service, Ministry of Health and Population, Government of Nepal, Kathmandu, Nepal. Paul van Donkelaar School of Health and Exercise Sciences, University of British Columbia, Kelowna, BC, Canada.
dc.description.abstractAbstract: Background: The original Mini Cog was modified to make it applicable to non-literates as well. However the reliability and validity of the modified mini cog (MMC) has not been examined. Therefore, we aimed to investigate the intra- and inter-rater reliability, criterion validity, sensitivity and specificity of the MMC. Methods: In this methodological and repeated measures design, elderly individuals (>60 years) with no neurological diagnosis or adults (>18 years) with neurological diagnosis were recruited from a tertiary hospital and the local community using purposive and snowball sampling. One of the raters administered the MMC twice (one week apart). Another rater administered the MMC and the Rowland Universal Dementia Assessment Scale (RUDAS) once during the first assessment session. Results: The ICC for consistency of a rater across the tests and absolute agreement between two raters ranged from 0.97-0.99. The MMC scores of two raters were not significantly different. The MMC was able to differentiate between elderly participants with no neurological diagnosis and adult participants with neurological diagnosis. A significant correlation (Coefficients: 0.52-0.68) was found between the MMC and RUDAS. The sensitivity and specificity of the MMC were 86% and 70% respectively. The cutoff score of the MMC was found ? 3. Conclusions: We demonstrated an excellent intra- and inter-rater reliability, and adequate criterion validity, sensitivity and specificity of the MMC. The MMC was also able to discriminate various groups having varied level of cognitive dysfunction. However, further studies are warranted to get more insight into the value of this instrument.
dc.identifierhttps://doi.org/10.33314/jnhrc.v23i02.4867
dc.identifier.urihttps://hdl.handle.net/20.500.14572/7628
dc.language.isoen_US
dc.publisherNepal Health Research Council
dc.subjectModified mini cog
dc.subjectReliability
dc.subjectSensitivity
dc.subjectSpecificity
dc.subjectValidity
dc.titleReliability and Validity of the Modified Mini Cog: A Measure for Screening Cognitive Functions in Literates and Non-literates
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage255
oaire.citation.startPage247
relation.isJournalIssueOfPublication5df7ea21-413e-4c7e-92f6-f85d6e7a64ef
relation.isJournalIssueOfPublication.latestForDiscovery5df7ea21-413e-4c7e-92f6-f85d6e7a64ef
relation.isJournalOfPublication40bd2739-8b19-447c-be60-723a1bdd1dcd

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
247-255.pdf
Size:
357.33 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections