Publication:
Micro ESR in the evaluation of neonatal sepsis

creativeworkseries.issnISSN (Print) : 1993-2979 | ISSN (Online) : 1993-2987
dc.contributor.authorPaudel, KP
dc.contributor.authorAdhikari, RK
dc.date.accessioned2026-06-11T05:49:42Z
dc.date.available2026-06-11T05:49:42Z
dc.date.issued2011
dc.descriptionKP Paudel Kanti Children’s Hospital, Maharajgunj Kathmandu and Department of Paediatrics, Tribhuvan University Teaching Hospital, Institute of Medicine, Kathmandu, Nepal RK Adhikari Kanti Children’s Hospital, Maharajgunj Kathmandu and Department of Paediatrics, Tribhuvan University Teaching Hospital, Institute of Medicine, Kathmandu, Nepal
dc.description.abstractAbstract Introduction: Neonatal sepsis is a major cause of neonatal morbidity and mortality in the developing countries like Nepal. Early diagnosis and treatment is crucial for the outcome but it is difficult in many situations especially in places with limited resources. Objective of this study is to evaluate the role of micro ESR in the diagnosis of neonatal sepsis Methods: A prospective analytical study was done where newborns with suspected sepsis admitted for septic work up and IV antibiotics were included in the study. Micro ESR was measured with relevant septic screening investigations. The micro ESR value was compared to age specific normal values and the results were compared with various clinical presentations, laboratory findings and outcome variables. Results: Out of 111 babies micro ESR was elevated in 63 babies and blood culture was positive in 15 cases and meningitis was present in 8 cases. Total proven cases were 16 and probable sepsis were 34. Correlation of elevated micro ESR was statistically significant with PROM >18 hours, presence of clinical symptoms, clinical and systemic signs. It had significant clinical association with blood culture and CSF findings. The sensitivity, specificity, positive and negative predictive value compared with blood culture was 100%, 47.5%, 15.6% and 20.8%, comparing with proven or no sepsis cases was 70.5%, 48.1%, 36.9% and 50% respectively. Conclusions: Micro ESR is simple cheap and relatively sensitive, specific with good negative predictive value in the prediction of neonatal sepsis and can be useful test in settings with limited resources. Keywords: Micro ESR, neonate, sepsis
dc.identifierhttps://doi.org/10.59779/jiomnepal.420
dc.identifier.urihttps://hdl.handle.net/20.500.14572/6435
dc.language.isoen_US
dc.publisherInstitute of Medicine
dc.subjectMicro ESR
dc.subjectneonate
dc.subjectsepsis
dc.titleMicro ESR in the evaluation of neonatal sepsis
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage21
oaire.citation.startPage17
relation.isJournalIssueOfPublicationa14e8358-bcd8-40d8-9366-45fb7d406a22
relation.isJournalIssueOfPublication.latestForDiscoverya14e8358-bcd8-40d8-9366-45fb7d406a22
relation.isJournalOfPublicationa9ba45d9-ee33-4a6b-b1fc-6626b87eec6c

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
17-21.pdf
Size:
132.39 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections