Article:
A comparative study of platelet counts by automated and manual method in patients with thrombocytopenia and thrombocytosis

creativeworkseries.issnOnline ISSN: 2676-1424; Print ISSN: 2676-1319
dc.contributor.authorPathak, Rakesh
dc.contributor.authorPudasaini, Sujata
dc.contributor.authorKharel, Manish
dc.contributor.authorKunwar, Saroj
dc.creator.affiliationDepartment of Pathology, Nepal Medical College Teaching Hospital, Attarkhel, Gokarneshwor-8, Kathmandu
dc.creator.affiliationDepartment of Pathology, Nepal Medical College Teaching Hospital, Attarkhel, Gokarneshwor-8, Kathmandu
dc.creator.affiliationDepartment of Pathology, Nepal Medical College Teaching Hospital, Attarkhel, Gokarneshwor-8, Kathmandu
dc.creator.affiliationDepartment of Laboratory Medicine, Nepal Medical College Teaching Hospital, Attarkhel, Gokarneshwor-8, Kathmandu
dc.date.accessioned2026-10-08T07:37:44Z
dc.date.available2026-10-08T07:37:44Z
dc.date.issued2025
dc.description.abstractAbstract: Platelet count is a vital parameter in the diagnosis and management of hematological disorders such as thrombocytopenia and thrombocytosis. Although automated hematology analyzers offer rapid and efficient platelet counting, their accuracy can be compromised in cases involving platelet clumping or morphological abnormalities, making manual methods still relevant for precise evaluation. This study aimed to evaluate the correlation and reliability of automated, Neubauer manual, and peripheral blood smear (PBS) methods for platelet counting. A hospital-based cross-sectional study was conducted over six months, including 321 patients undergoing platelet count testing, of whom 246 had thrombocytopenia and 75 had thrombocytosis. Platelet counts were measured using an automated hematology analyzer (Sysmex XN-550, Japan), Neubauer manual counting method, and PBS examination. Data were analyzed to compare and assess the correlation between the methods. The mean platelet count of thrombocytopenic cases across different methods were automated (79000± 33296/μl), manual (93900±40130/μl) and peripheral blood smear (91200±37560/μl), respectively. For thrombocytosis cases the mean platelet value across different methods were automated (597000±148000/μl), manual (590000± 164000/μl) and peripheral blood smear (601000±180000/μl), respectively. A strong correlation was observed among the methods (Neubauer manual vs automated, r=0.77, p=0.01 and Neubauer manual vs PBS r=0.78, p=0.01). There is no significant difference in platelet value between the methods. While all three methods exhibit strong agreement, the automated method may underreport platelet counts in thrombocytopenic samples. Neubauer manual and PBS methods remain valuable for confirming the low platelet counts.
dc.identifier.doihttps://doi.org/10.3126/nmcj.v27i2.80538
dc.identifier.urihttps://hdl.handle.net/20.500.14572/8052
dc.language.isoen_US
dc.publisherNepal Medical College Pvt. Ltd.
dc.subjectAutomated method
dc.subjectNeubauer manual method
dc.subjectPlatelet count
dc.subjectPeripheral blood smear
dc.subjectThrombocytopenia
dc.subjectThrombocytosis
dc.titleA comparative study of platelet counts by automated and manual method in patients with thrombocytopenia and thrombocytosis
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage118
oaire.citation.startPage113
relation.isJournalIssueOfPublicationd6f8668b-63e4-40af-9dee-3e2b689fa22a
relation.isJournalIssueOfPublication.latestForDiscoveryd6f8668b-63e4-40af-9dee-3e2b689fa22a
relation.isJournalOfPublication865934c8-5e95-468c-8ca6-7bb2529e4064

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
113-118+Rakesh+Pathak.pdf
Size:
637.58 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections