Publication:
Role of Magnetic Resonance Cholangiopancreatography in the Evaluation of Obstructive Jaundice

creativeworkseries.issn1812-2027
dc.contributor.authorKarki, S
dc.contributor.authorPhuyal, A
dc.contributor.authorPaudel, RC
dc.contributor.authorBhandari, A
dc.contributor.authorDahal, MR
dc.date.accessioned2025-12-11T06:09:09Z
dc.date.available2025-12-11T06:09:09Z
dc.date.issued2021
dc.descriptionKarki S, Phuyal A, Paudel RC, Bhandari A, Dahal MR Department of Radiodiagnosis and Imaging Kathmandu University School of Medical Sciences, Dhulikhel Hospital, Kathmandu University Hospital, Dhulikhel, Kavre, Nepal.
dc.description.abstractABSTRACT Background Magnetic Resonance Cholangiopancreatography is a reliable and highly sensitive imaging modality in the diagnosis of Obstructive jaundice. Objective To evaluate the diagnostic accuracy of Magnetic Resonance Cholangiopancreatography as compared to Endoscopic Retrograde Cholangiopancreatography. Method A prospective, analytical study was conducted in the Department of Radiodiagnosis and Imaging at Dhulikhel Hospital between October 2018 and December 2020. Altogether 100 patients of all ages with obstructive jaundice undergoing Magnetic Resonance Cholangiopancreatography and Endoscopic Retrograde Cholangiopancreatography were included. The causes of obstructive jaundice as identified by Magnetic Resonance Cholangiopancreatography were compared to that of Endoscopic Retrograde Cholangiopancreatography considering Endoscopic Retrograde Cholangiopancreatography as gold standard for the diagnosis. Result Magnetic Resonance Cholangiopancreatography revealed choledocholithiasis in 60 (60%) patients, benign stricture – 14(14%), malignant stricture-11(11%), peri- ampullary carcinoma in 8(8%) and normal study in 4(4%) patients. Endoscopic Retrograde Cholangiopancreatography showed choledocholithiasis in 59(59%) patients, strictures (benign in 13%, malignant in 10%), ascariasis in 3(3%) and normal findings in 5(5%) patients. The sensitivity, specificity, positive predictive value and negative predictive value of Magnetic Resonance Cholangiopancreatography in detecting choledocholithiasis were 96.6%, 92.3%, 95%, and 95%. The same values for benign strictures were 92.3%, 97.7%, 85.7% and 98.9%, whereas those for malignant strictures were 90.9%, 98.8%, 90.9% and 98.8%. All values were 100% for peri-ampullary carcinoma and ascariasis. Hence, Magnetic Resonance Cholangiopancreatography showed good accuracy for detecting causes of obstructive jaundice (p < 0.05) as compared to Endoscopic Retrograde Cholangiopancreatography. Conclusion Magnetic Resonance Cholangiopancreatography is an accurate, non-invasive technique in evaluation of obstructive jaundice and offers similar diagnostic value compared to Endoscopic Retrograde Cholangiopancreatography. KEY WORDS Endoscopic retrograde, Magnetic resonance cholangiopancreatography, Obstructive jaundice
dc.identifier.urihttps://hdl.handle.net/20.500.14572/3529
dc.language.isoen_US
dc.publisherKathmandu University
dc.subjectEndoscopic retrograde
dc.subjectMagnetic resonance cholangiopancreatography
dc.subjectObstructive jaundice
dc.titleRole of Magnetic Resonance Cholangiopancreatography in the Evaluation of Obstructive Jaundice
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage40
oaire.citation.startPage35
relation.isJournalIssueOfPublicationdd71608f-309e-4987-a5c2-264b37b74bcb
relation.isJournalIssueOfPublication.latestForDiscoverydd71608f-309e-4987-a5c2-264b37b74bcb
relation.isJournalOfPublicationa782b7ff-cf89-4178-ad1c-11ed89cfe1bd

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
35-40.pdf
Size:
696.31 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections