Publication:
Correlation Of Linear Measurements Of Spleen With Splenic Volume in Computed Tomography

creativeworkseries.issnISSN (Print) : 1993-2979 | ISSN (Online) : 1993-2987
dc.contributor.authorSuwal, S
dc.contributor.authorSubedi, K
dc.contributor.authorGurung, G
dc.date.accessioned2026-04-16T06:16:40Z
dc.date.available2026-04-16T06:16:40Z
dc.date.issued2018
dc.descriptionSuwal S, Subedi K, Gurung G. Department of Radiology, Tribhuvan University Teaching Hospital, Kathmandu, Nepal
dc.description.abstractAbstract Introduction: The purpose of this study was to assess the normal linear measurements of spleen in Nepalese adults by Computed Tomography (CT) and their correlation with splenic volume. Methods: This was a prospective cross sectional observational study done in 264 peoples undergoing abdominal CT examination for various clinical indications not pertaining to spleen, in Department of Radiology & Imaging, Tribhuvan University Teaching Hospital (TUTH). Four linear measurements of spleen were obtained in axial plane. Craniocaudal length of the spleen was also obtained. The volume was obtained by adding cross-sectional area of spleen from 10 mm contiguous axial images and multiplying them with the slice thickness. The relationships between various linear measurements of spleen with spleenic volume were derived. Results: The mean length of spleen along long axis was 9.3 +/-1.3 cm, and the mean length along the craniocaudal axis was 7.6+/-1.5 cm. The mean width, maximum thickness, and thickness at hilum of the spleen were 9.3 +/- 1.7 cm, 5.1+/-1.2 and 3.2+/-0.6 cm respectively. The mean splenic volume was 151.20 cm3 ± 59.62 cm3. Significant positive correlations were noted between linear measurements and volume, the strongest being the width followed by the craniocaudal length. Conclusion: Linear measurements of the spleen in CT show stong correlation with volume and hence can replace the splenic volume measurements while defining splenomegaly. Key words: Computed Tomography, Spleen, Linear measurement, Volume
dc.identifierhttps://doi.org/10.59779/jiomnepal.824
dc.identifier.urihttps://hdl.handle.net/20.500.14572/5763
dc.language.isoen_US
dc.publisherInstitute of Medicine
dc.subjectComputed Tomography
dc.subjectSpleen
dc.subjectLinear measurement
dc.subjectVolume
dc.titleCorrelation Of Linear Measurements Of Spleen With Splenic Volume in Computed Tomography
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage67
oaire.citation.startPage64
relation.isJournalIssueOfPublicationefd6a6b6-4948-4da4-8186-5ae4166f1254
relation.isJournalIssueOfPublication.latestForDiscoveryefd6a6b6-4948-4da4-8186-5ae4166f1254
relation.isJournalOfPublicationa9ba45d9-ee33-4a6b-b1fc-6626b87eec6c

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
64-67.pdf
Size:
290.7 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections