Article: Retrieval of Broken Umbilical Venous Catheter Fragment in a VLBW Neonate
Abstract:
Fracture of umbilical venous catheters is a serious uncommon complication. We are reporting a 31+4 week male neonate weighing 1390 gm with a broken umbilical venous catheter and successful retrieval of the catheter by an open surgical technique.
Md Habibullah SK
Senior Resident, Department of Neonatology, IPGME & R and SSKM Hospital, Kolkata 700020, India
Bijan Saha
Associate Professor, Department of Neonatology, IPGME & R and SSKM Hospital, Kolkata-700020, India
Ashadur Zamal
Post doctoral Trainee, Department of Neonatology, IPGME&R and SSKM Hospital, Kolkata 700020, India
Sayantan Saha
Divisional Medical Officer, B.R. Singh Hospital, Kolkata, India.
Keywords
Breaking, Newborn, Surgical exploration, Umbilical catheter
Identifier
https://doi.org/10.60086/jnps500
Citation
Collections