Publication:
Mean Amplitude of Diurnal Variation of Sub-Foveal Choroidal Thickness among Adults with Healthy Eyes Visiting Outpatient Department of a Tertiary Eye Care Centre

creativeworkseries.issnJNMA Print ISSN: 0028-2715; Online ISSN: 1815-672X
dc.contributor.authorKaiti, Raju
dc.contributor.authorBajgai, Priya
dc.contributor.authorShyangbo, Ranjila
dc.date.accessioned2025-08-17T06:58:13Z
dc.date.available2025-08-17T06:58:13Z
dc.date.issued2024
dc.descriptionAuthors Raju Kaiti Department of Optometry, Nepal Eye Hospital, Tripureshwor, Kathmandu, Nepal Priya Bajgai Department of Ophthalmology, Nepal Eye Hospital, Tripureshwor, Kathmandu, Nepal Ranjila Shyangbo Department of Optometry, National Academy of Medical Sciences, Mahaboudha, Kathmandu, Nepal
dc.description.abstractAbstract Introduction: The choroid, particularly the choroidal vasculature, plays an important role in the pathophysiology of various ocular diseases. Diurnal variation in the thickness of the choroid has been reported in previous studies. This study aimed to find the mean amplitude of diurnal variation of sub-foveal choroidal thickness among adults with healthy eyes visiting the outpatient Department of a tertiary eye care centre. Methods: A descriptive cross-sectional study was conducted among adults with healthy eyes presenting to the outpatient Department of a tertiary eye care centre from 1 February 2023 to 3 June 2023 after obtaining ethical approval from the Institutional Review Committee. After a comprehensive medical eye examination, sub-foveal choroidal thickness measurement was performed using enhanced depth imaging optical coherence tomography at the baseline and subsequent interval afterwards. A convenience sampling method was used. The point estimate was calculated at a 95% Confidence Interval. Results: Among 60 eyes, the mean amplitude of the diurnal variation of subfoveal choroidal thickness was 35.16±14.08 microns (31.59-38.72, 95% Confidence Interval). The mean amplitude for the right eye was 36.30±14.08 microns, and for the left eye, it was 34.23±14.08 microns Conclusions: The amplitude of diurnal variation of subfoveal choroidal thickness from this study was found to be similar to other studies done in international settings.
dc.identifierhttps://doi.org/10.31729/jnma.8436
dc.identifier.urihttps://hdl.handle.net/20.500.14572/1668
dc.language.isoen_US
dc.publisherNepal Medical Association
dc.titleMean Amplitude of Diurnal Variation of Sub-Foveal Choroidal Thickness among Adults with Healthy Eyes Visiting Outpatient Department of a Tertiary Eye Care Centre
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage109
oaire.citation.startPage106
relation.isJournalIssueOfPublicationace16a70-754f-435d-9d8a-18dc78f35b8e
relation.isJournalIssueOfPublication.latestForDiscoveryace16a70-754f-435d-9d8a-18dc78f35b8e
relation.isJournalOfPublicatione6e146a0-0ece-4aba-aa0a-6ccfbd10a12a

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
106-109.pdf
Size:
351.21 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections