Publication:
A Study of Diagnostic Yield, Efficacy and Complications of Ultrasound Guided Renal Biopsy in Different Renal Pathologies

creativeworkseries.issnISSN (Print) : 1993-2979 | ISSN (Online) : 1993-2987
dc.contributor.authorChataut, D
dc.contributor.authorSubedi, K
dc.contributor.authorLohani, B
dc.date.accessioned2026-05-13T05:27:49Z
dc.date.available2026-05-13T05:27:49Z
dc.date.issued2014
dc.descriptionD Chataut Department of Radiology, Tribhuvan University Teaching Hospital, Kathmandu, Nepal K Subedi Department of Radiology, Tribhuvan University Teaching Hospital, Kathmandu, Nepal B Lohani Department of Radiology, Tribhuvan University Teaching Hospital, Kathmandu, Nepal
dc.description.abstractAbstract Introduction: Renal biopsy is an integral part of modern nephrology practice, being indicated in renal diseases in both native and transplanted kidneys. The purpose of this study was to automated biopsy gun. Methods: This was a prospective cross-sectional study involving 184 patients including renal transplant recipients. These patients, with new onset renal symptoms or deteriorating renal function post-transplant, underwent freehand real time ultrasound guided renal biopsy with 18 gauge automated biopsy gun. The diagnostic yield, pathological and immunohistochemistry diagnosis and complications of the procedure were analyzed. Results: 184 patients underwent the ultrasound guided biopsy, 17 were renal transplant recipients. Male and female ratio was almost equal (51.1% and 48.9%, respectively). Most patients were in the age group of 20-40 years. Most cases presented clinically with nephrotic syndrome (38.04%), followed by an equal number of lupus nephritis and nonnephrotic range proteinuria. The average number of glomeruli in the biopsy tissue was 11.8 per specimen. The average length of biopsy tissue was 1.15 cm in native kidneys and 0.9 cm in transplant kidneys. Renal biopsy yielded a pathological diagnosis in 97.2% of cases, with adequate sample for diagnosis in 98.9% of cases. Major life threatening complication was noted in a single patient. Rest of the patients showed minor or no complications. Conclusion: Ultrasound guided percutaneous biopsy with automated biopsy gun is modality of choice for renal biopsy since it has the greatest yield, highest efficacy and least serious complication rates. Keywords: glomeruli, nephrotic syndrome, renal biopsy, ultrasound
dc.identifierhttps://doi.org/10.59779/jiomnepal.588
dc.identifier.urihttps://hdl.handle.net/20.500.14572/6070
dc.language.isoen_US
dc.publisherInstitute of Medicine
dc.subjectglomeruli
dc.subjectnephrotic syndrome
dc.subjectrenal biopsy
dc.subjectultrasound
dc.titleA Study of Diagnostic Yield, Efficacy and Complications of Ultrasound Guided Renal Biopsy in Different Renal Pathologies
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage63
oaire.citation.startPage58
relation.isJournalIssueOfPublication29e51979-9618-4dd8-9737-216e83305d97
relation.isJournalIssueOfPublication.latestForDiscovery29e51979-9618-4dd8-9737-216e83305d97
relation.isJournalOfPublicationa9ba45d9-ee33-4a6b-b1fc-6626b87eec6c

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
58-63.pdf
Size:
1.41 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections