Article:
The effect of vacuum on venous drainage: an experimental evaluation on pediatric venous cannulas and tubing systems

creativeworkseries.issnJNMA Print ISSN: 0028-2715; Online ISSN: 1815-672X
dc.contributor.authorVida, Vladimiro L
dc.contributor.authorBhattarai, A
dc.contributor.authorSimone Speggiorin
dc.contributor.authorFabio Zanella
dc.contributor.authorGiovanni Stellin
dc.creator.affiliationPediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic and Vascular Surgery, University of Padua, Italy.
dc.creator.affiliationPediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic and Vascular Surgery, University of Padua, Italy.
dc.creator.affiliationPediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic and Vascular Surgery, University of Padua, Italy,Cardiothoracic Surgery Department, The Great Ormond Street Hospital for Children NHS Trust, London,
dc.creator.affiliationCardiac Perfusion Unit, University of Padua, Italy.
dc.creator.affiliationPediatric and Congenital Cardiac Surgery Unit, Department of Cardiac, Thoracic and Vascular Surgery, University of Padua, Italy.
dc.date.accessioned2026-10-06T04:38:44Z
dc.date.available2026-10-06T04:38:44Z
dc.date.issued2014
dc.description.abstractAbstract Introduction: To observe how vacuum assisted venous drainage (VAVD) may influence the flow in a cardiopulmonary bypass circuit with different size of venous lines and cannulas. Methods: The experimental circuit was assembled to represent the cardiopulmonary bypass circuit routinely used during cardiac surgery. Wall suction was applied directly, modulated and measured into the venous reservoir. The blood flow was measured with a flow-meter positioned on the venous line. The circuit prime volume was replaced with group O date expired re-suspended red cells and Plasmalyte 148 to a hematocrit of 28% to 30%. Results: In an open circuit with gravity siphon venous drain, angled cannulae drain more than straight ones regardless the amount of suction applied to the venous line (16 Fr straight cannula (S) drains 90 ml/min less than a 16 Fr angled (A) with a siphon gravity). The same flow can be obtained with lower cannula size and higher suction (i.e. 12 A with and -30 mmHg). Tables have been created to list how the flow varies according to the size of the cannulas, the size of the venous tubes, and the amount of suction applied to the system. Conclusions: Vacuum assisted venous drainage allows the use of smaller cannulae and venous lines to maintain a good venous return, which is very useful during minimally invasive approaches. The present study should be considered as a preliminary attempt to create a scientific-based starting point for a uniform the use of VAVD. Keywords: Cardio-pulmonary bypass; Experimental study; Vacuum assisted drainage.
dc.identifier.doihttps://doi.org/10.31729/jnma.2794
dc.identifier.urihttps://hdl.handle.net/20.500.14572/7961
dc.language.isoen_US
dc.publisherNepal Medical Association
dc.subjectCardio-pulmonary bypass
dc.subjectExperimental study
dc.subjectVacuum assisted drainage
dc.titleThe effect of vacuum on venous drainage: an experimental evaluation on pediatric venous cannulas and tubing systems
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage966
oaire.citation.startPage960
relation.isJournalIssueOfPublication52658252-c299-4e73-8477-994dfd16a0d2
relation.isJournalIssueOfPublication.latestForDiscovery52658252-c299-4e73-8477-994dfd16a0d2
relation.isJournalOfPublicatione6e146a0-0ece-4aba-aa0a-6ccfbd10a12a

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
960-966.pdf
Size:
971.59 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections