Article:
Pre-operative ultrasonographic evaluation of inferior vena cava collapsibility index as a predictor for hypotension after spinal anaesthesia

creativeworkseries.issnOnline ISSN: 2676-1424; Print ISSN: 2676-1319
dc.contributor.authorYadav, Rajiv
dc.contributor.authorYadav, Ila
dc.contributor.authorBharti, Srijan
dc.contributor.authorSingh, Sujeet
dc.creator.affiliationDepartment of Anesthesia, Nepal Medical College, Attarkhel, Gokarneshwor-8, Kathmandu
dc.creator.affiliationTribhuvan University, Kathmandu
dc.creator.affiliationDepartment of Anesthesia, Nepal Medical College, Attarkhel, Gokarneshwor-8, Kathmandu
dc.creator.affiliationInstitute of Medicine, Kathmandu
dc.date.accessioned2026-10-09T10:37:54Z
dc.date.available2026-10-09T10:37:54Z
dc.date.issued2025
dc.description.abstractAbstract: Postspinal anaesthesia hypotension is a common side effect and can lead to significant morbidity and mortality. Inferior venacava collapsibility index (IVC-CI) and diameter of the inferior venacava (IVC) are two widely used parameters for assessing the intravascular volume status. In this study, we evaluated inferior vena cava collapsibility before surgery topredict hypotension after spinal anaesthesia. In this hospital based observational study, 80 patients aged 18-60 years of ASA physical status I and II undergoing surgery below umbilicus under spinal anesthesia. The IVC-CI and IVC diameter were measured using ultrasound pre-operatively. After administering spinal anaesthesia, haemodynamic data were collected till 18 min. Our general objective was to evaluate the predictive value of IVC-CI for detecting post-spinal hypotension and specific objectives were to to measure IVC diameter, calculate IVC-CI, measure MAP, SBP, DBP. We constructed the receiver operator characteristic (ROC) curves for IVCCI and obtained the best cut-off values. The post spinal hypotension occurred in 18 (22.5%) patients. IVC-CI had a sensitivity of 18.0%, a specificity of 76.0% and a positive predictive value of 18.0%, negative predictive value of 76.0% for predicting hypotension following spinal anesthesia at a cut off value of >42.0%. The IVC-CI had poor diagnostic accuracy for prediction of hypotension after spinal anesthesia for surgery below umbilicus.
dc.identifier.doihttps://doi.org/10.3126/nmcj.v27i1.77540
dc.identifier.urihttps://hdl.handle.net/20.500.14572/8085
dc.language.isoen_US
dc.publisherNepal Medical College Pvt. Ltd.
dc.subjectInferior venacava collapsibility index
dc.subjectInferior vanacava diameter
dc.subjectPostspinal hypotension
dc.subjectSpinal anesthesia
dc.titlePre-operative ultrasonographic evaluation of inferior vena cava collapsibility index as a predictor for hypotension after spinal anaesthesia
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage38
oaire.citation.startPage34
relation.isJournalIssueOfPublication3a55177c-653e-4078-9e98-a90eea759d29
relation.isJournalIssueOfPublication.latestForDiscovery3a55177c-653e-4078-9e98-a90eea759d29
relation.isJournalOfPublication865934c8-5e95-468c-8ca6-7bb2529e4064

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
34-38+Rajiv+Yadav.pdf
Size:
270.69 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections