Article:
Per-operative Instrument Failure in Lumbar Spine Surgery

creativeworkseries.issnISSN (Print) : 1993-2979 | ISSN (Online) : 1993-2987
dc.contributor.authorPokharel, R K
dc.contributor.authorLakhey, R B
dc.contributor.authorKafle, D
dc.contributor.authorPokharel, B
dc.contributor.authorDhakal, R K
dc.contributor.authorSigdel, A
dc.contributor.authorLalit, T
dc.contributor.authorShah, L L
dc.contributor.authorKafle, D
dc.date.accessioned2026-05-20T05:25:24Z
dc.date.available2026-05-20T05:25:24Z
dc.date.issued2013
dc.descriptionR K Pokharel Department of Orthopaedic and Trauma Surgery (Spine Unit), Institute of Medicine, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Kathmandu, Nepal R B Lakhey Department of Orthopaedic and Trauma Surgery (Spine Unit), Institute of Medicine, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Kathmandu, Nepal B Pokharel Department of Orthopaedic and Trauma Surgery (Spine Unit), Institute of Medicine, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Kathmandu, Nepal R K Dhakal Department of Orthopaedic and Trauma Surgery (Spine Unit), Institute of Medicine, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Kathmandu, Nepal A Sigdel Department of Orthopaedic and Trauma Surgery (Spine Unit), Institute of Medicine, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Kathmandu, Nepal T Lalit Department of Orthopaedic and Trauma Surgery (Spine Unit), Institute of Medicine, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Kathmandu, Nepal LL Shah Department of Orthopaedic and Trauma Surgery (Spine Unit), Institute of Medicine, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Kathmandu, Nepal D Kafle Department of Orthopaedic and Trauma Surgery (Spine Unit), Institute of Medicine, Maharajgunj Medical Campus, Tribhuvan University Teaching Hospital, Kathmandu, Nepal
dc.description.abstractAbstract Breakage of hardware is not an uncommon complication in spine surgery practice. Pedicle screw breakage is the commonest instrument failure encountered in spine surgery, and different relatively simple, techniques have been recommended to retrieve the threaded part of it. Per-operative breakage of an instrument like pedicle seeker and jaw of disc forceps is unpredictable and removal of an unthreaded smooth implant is difficult. We experienced breakage of the pedicle seeker while putting a pedicle screw in a case of spondylolisthesis and breakage of the mobile jaw of a disc forceps in another case of prolapsed intervertebral disc. Here we present an innovative technique of removal of the broken instrument through the pedicle. Regular maintenance and replacement of al old instrument is recommended. Keywords: per-operative instrument breakage, spine surgery
dc.identifierhttps://doi.org/10.59779/jiomnepal.638
dc.identifier.urihttps://hdl.handle.net/20.500.14572/6118
dc.language.isoen_US
dc.publisherInstitute of Medicine
dc.subjectper-operative instrument breakage
dc.subjectspine surgery
dc.titlePer-operative Instrument Failure in Lumbar Spine Surgery
dc.typeArticle
dspace.entity.typePublication
local.article.typeCase Report
oaire.citation.endPage104
oaire.citation.startPage101
relation.isJournalIssueOfPublication4c7059ac-900c-4673-bc59-61e668eda4bc
relation.isJournalIssueOfPublication.latestForDiscovery4c7059ac-900c-4673-bc59-61e668eda4bc
relation.isJournalOfPublicationa9ba45d9-ee33-4a6b-b1fc-6626b87eec6c

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
101-104.pdf
Size:
632.42 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections