Publication:
Diagnostic Accuracy and Safety Between two Needle Sizes in Percutaneous Trans-Thoracic Biopsy for the Evaluation of Pulmonary Lesions

creativeworkseries.issn1999-6217
dc.contributor.authorYodying, Jirawadee
dc.contributor.authorSunmahakhun, Chantham
dc.contributor.authorGhimire, Pradesh
dc.contributor.authorBista, Neha
dc.date.accessioned2025-07-27T09:29:19Z
dc.date.available2025-07-27T09:29:19Z
dc.date.issued2023
dc.descriptionJirawadee Yodying Department of Radiology, Intervention Radiology section, Siriraj Hospital, Bangkok noi, Mahidol University, Thailand Chantham Sunmahakhun Department of Radiology, Intervention Radiology section, Siriraj Hospital, Bangkok noi, Mahidol University, Thailand Pradesh Ghimire Department of Radiology, Intervention Radiology section, Chitwan Medical College, Bharatput-10, Tribhuvan University, Nepal Neha Bista Department of Radiology, Intervention Radiology section, Chitwan Medical College, Bharatput-10, Tribhuvan University, Nepal
dc.description.abstractAbstract Background: Percutaneous trans-thoracic lung biopsy has a crucial role in diagnosing lung lesions including lung cancer. However, there is no clear guideline regarding the needle size in percutaneous trans-thoracic lung biopsy. This study aims to evaluate the diagnostic accuracy and complication rate between two needle sizes for percutaneous trans-thoracic lung biopsy. Methods: A retrospective review of patients with lung lesions who underwent percutaneous trans-thoracic lung biopsy between November 2010 and December 2019 was performed. The demographic data, imaging finding, biopsy technique, complication and histologic outcome were recorded and analyzed. Propensity score matching was done to reduce bias in baseline characteristics. Results: Of 377 patients who underwent percutaneous trans-thoracic lung biopsy, 331 patients had complete information. The patients were divided in two groups, comprising of 153 patients in 18G needle group and 178 patients in 20G needle group. After propensity score matching, there were 126 patients left in each group. The diagnostic accuracy, sensitivity, specificity, positive predictive value and negative predictive value for 18G needle group were 92.9%, 98.1%, 65.0%, 93.7% and 86.7%, respectively. For 20G needle group, the diagnostic accuracy, sensitivity, specificity, predictive value and negative predictive value were 96.0%, 99.0%, 83.3%, 96.2% and 95.2%, respectively. The immediate complication rate was 35.7% and 31.7% in 18G and 20 G needle groups (p= 0.505), respectively. Conclusions: There was no difference in diagnostic accuracy and immediate complication rates between 18G and 20G needle use for percutaneous trans-thoracic lung biopsy. Keywords: Complication rates; diagnostic accuracy; needle sizes; percutaneous lung biopsy; propensity score matching.
dc.identifierhttps://doi.org/10.33314/jnhrc.v21i1.4598
dc.identifier.urihttps://hdl.handle.net/20.500.14572/775
dc.language.isoen_US
dc.publisherNepal Health Research Council
dc.titleDiagnostic Accuracy and Safety Between two Needle Sizes in Percutaneous Trans-Thoracic Biopsy for the Evaluation of Pulmonary Lesions
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage121
oaire.citation.startPage115
relation.isJournalIssueOfPublication0b756562-9f28-45a1-a148-be81ddb98bf5
relation.isJournalIssueOfPublication.latestForDiscovery0b756562-9f28-45a1-a148-be81ddb98bf5
relation.isJournalOfPublication40bd2739-8b19-447c-be60-723a1bdd1dcd

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
115-121.pdf
Size:
329.32 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections