Publication:
Study of sensitivity and specificity of five rapid plasma reagin test kits in syphilis

Date

2007

Article Type

Original Article

Journal Title

Journal ISSN

ISSN (Print) : 1993-2979 | ISSN (Online) : 1993-2987

Volume Title

Pages
Pages: 34 - 36

Publisher

Institute of Medicine

Research Projects

Organizational Units

Journal Issue

Abstract

Abstract Background: Syphilis caused by Treponema pallidum has been associated with humankind since ancient times. Materials and Methods: Blood samples from 408 healthy Nepalese male population was collected and tested to find out the sensitivity and specificity of five different (a, b, c, d and e) non treponemal syphilis serological test rapid plasma reagin (RPR) as well as for the screening of the healthy target group for syphilis. Results: Six subjects (1.47%) were found positive with the test and by Treponema pallidum Haemagglutination (TPHA) test was identified as a syphilitic subject. With the test kits a, c and d 34 false positive cases were detected. The sensitivity was 100%, and the specificity was 92% only. Whereas with test kits b and e only six true positive cases were detected thus making their sensitivity and specificity 100%. Conclusion: Therefore, it is concluded that test kits a, c and d should only be used for the screening purpose. On the other hand, the test kits b and e can be used for the diagnostic purpose. Keywords: RPR, TPHA, syphilis, sensitivity, specificity

Description

B. Shrestha Department of Microbiology Tribhuvan University Tri-Chandra Campus

Keywords

RPR, TPHA, syphilis, sensitivity, specificity

Identifier

https://doi.org/10.59779/jiomnepal.278

Citation

Collections