Publication:
Removal of central venous catheter fragment embolus in a young male

creativeworkseries.issn1812-2027
dc.contributor.authorPB, Thapa
dc.contributor.authorR, Shrestha
dc.contributor.authorDR, Singh
dc.contributor.authorSK, Sharma
dc.date.accessioned2025-07-23T07:22:36Z
dc.date.available2025-07-23T07:22:36Z
dc.date.issued2006
dc.descriptionThapa PB, Shrestha R, Singh DR, Sharma SK Department of Surgery, Kathmandu Medical College, Teaching Hospital
dc.description.abstractA 22 years male admitted with severe pancreatitis with central venous catheter implanted for central venous pressure monitoring and for providing total parental nutrition developed catheter fragment embolus due to accidental fracture of the same while manipulating it. Non surgical retrieval of the same was done by radiological intervention without any complication. Key words: intravascular catheter fragments, transfemoral venous approach, interventional procedures
dc.identifier.urihttps://hdl.handle.net/20.500.14572/565
dc.language.isoen_US
dc.publisherKathmandu University
dc.titleRemoval of central venous catheter fragment embolus in a young male
dc.typeArticle
dspace.entity.typePublication
local.article.typeCase Report
oaire.citation.endPage341
oaire.citation.startPage340
relation.isJournalIssueOfPublication63510cea-3395-4059-86a7-2b9d0d843bf1
relation.isJournalIssueOfPublication.latestForDiscovery63510cea-3395-4059-86a7-2b9d0d843bf1
relation.isJournalOfPublicationa782b7ff-cf89-4178-ad1c-11ed89cfe1bd

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
340-341.pdf
Size:
96.91 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections