Publication:
Accuracy of 7-8-9 Rule for Endotracheal Tube Placement in Nepalese Neonates

creativeworkseries.issnISSN 1990-7974 eISSN 1990-7982
dc.contributor.authorPaudel, KP
dc.contributor.authorNepal, D
dc.contributor.authorMahaseth, C
dc.date.accessioned2026-05-29T08:12:53Z
dc.date.available2026-05-29T08:12:53Z
dc.date.issued2011
dc.descriptionKP Paudel Department of Paediatric Medicine Kanti Children’s Hospital, Maharajgunj, Kathmandu, D Nepal Associate Professor National Acaemy of Medical Sciences (NAMS), Department of Paediatric Medicine Kanti Children’s Hospital, Maharajgunj, Kathmandu, C Mahaseth Professor, National Academy of Medical Sciences, Department of Paediatric Medicine Kanti Children’s Hospital, Maharajgunj, Kathmandu
dc.description.abstractAbstract: Introduction: Neonatal intubation is done for cardiopulmonary resuscitation, hypoxemia, and hypercapnia, for surfactant therapy or for airway protection. When correctly placed, endotracheal tube (ETT) tip should be at mid tracheal position which is half way between the clavicles and the carina to prevent complications of ventilation. Objective: To assess the accuracy of 7-8-9 Rule in neonates at Kanti Children’s hospital. Methodology: Prospective observational study was conducted in neonates who required oral intubations from July 2009 to December 2009 at NICU of Kanti Children’s Hospital. The initial ETT depth of insertion was determined using admission weight in the 7-8-9 Rule calculation. This depth was compared to the midtracheal depth to determine clinical accuracy of the 7-8-9 Rule. Results: Mean gestation age of the 69 infants was 36.01 weeks (26 to 42 weeks) and weight was 2411 g( 900 g to 3800 g ). 7 (10.1%) neonates weighed 1000 g or less, 19 (27.5%) weighed between 1001 to 2000 g, 31 ( 44.9%) weighed between 2001 to 3000 g, 12(17.4%) weighed between 3001 to 4000 g. The accuracy of 7-8-9 rule in clinical setting with auscultation and Chest x-ray resulted in ETT depth 0.11 cm above midtracheal position. (-1.5 to 1.5 cm). Using this rule ET tube was placed 0.11 cm above the mid tracheal position. Conclusions: The 7-8-9 Rule appears to be an accurate clinical method for endotracheal tube placement in Nepalese neonates.
dc.identifierhttps://doi.org/10.3126/jnps.v31i3.4299
dc.identifier.urihttps://hdl.handle.net/20.500.14572/6300
dc.language.isoen_US
dc.publisherNepal Paediatric Society (JNPS)
dc.subjectIntubation
dc.subjectNeonate
dc.subjectMid Tracheal Position
dc.titleAccuracy of 7-8-9 Rule for Endotracheal Tube Placement in Nepalese Neonates
dc.typeArticle
dspace.entity.typePublication
local.article.typeOriginal Article
oaire.citation.endPage179
oaire.citation.startPage175
relation.isJournalIssueOfPublication067683ab-0fff-4aea-962b-fe5b9ea554dc
relation.isJournalIssueOfPublication.latestForDiscovery067683ab-0fff-4aea-962b-fe5b9ea554dc
relation.isJournalOfPublication6f9be05c-05a9-4a3e-a5b5-a19a15ab042c

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
175-179.pdf
Size:
154.04 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.86 KB
Format:
Item-specific license agreed to upon submission
Description:

Collections